HI-9829 MULTIPARAMETER PH/ISE/EC/DO/TURBIDITY WATERPROOF METER (GPS OPTION AVAILABLE)
HI-9829-02
The HI-9829 is a highly customizable piece of equipment. Please telephone Hanna on +46 300-404018 to discuss your requirements and to get a price.
The HI-9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters.
The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature.
The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use.
The HI-9829 is highly customisable and supplied with all necessary accessories, packaged in a durable carrying case.
- Built in GPS Receiver
- Colour Coded, field replaceable sensors
- Waterproof protection
- Logging – from probe to meter
- Fast Tracker – Tag Identification system
- Sensor Check™ - Auto-recognition of all sensors
- GLP features – Meets good laboratory practices
- Connectivity – PC compatible via USB
- Help feature – On-screen user guides
- Backlight – Backlit, graphic LCD display
- Waterproof – waterproof casing
Meter with or without GPS
Built in GPS Receiver
- 12 channel GPS receiver and antenna
- Tracks location using satellites to within 30 feet
- Latitude and longitude recorded with readings
- Location naming for GPS coordinates
- Distance from current location to stored location
- HI-929829 software supplied integrates data collected with Google™ maps
- Measurement readings including GPS coordinates
- Date and time
- Named locations and remarks
- Sample number
(Google™ maps is a registered trademark of Google™, HANNA Instruments Ltd; has no affiliation with Google™).
Colour Coded, Field Replaceable Sensors
Dissolved Oxygen
- HI-7609829-2 DO
pH
- HI-7609829-0 pH
- HI-7609829-1 pH/ORP
Conductivity and Turbidity
- HI-7609829-4 EC/Turbidity
ISE
- HI-7609829-0 Ammonium ISE
- HI-7609829-11 Chloride ISE
- HI-7609829-12 Nitrate ISE
Conductivity
- HI-7609829-3 EC
Two probes to choose from (Basic or Logging)
The HI-7609829 (basic) and HI-7629829 (logging) are multiparameter probes for use with the HI-9829 portable meter. It is an option to choose which probe will be supplied with the HI-9829. By default the HI-9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.
HI-7629829 Autonomously Logging Probe
- Same as basic probe but with logging capability
- Logs data independent of HI-9829 meter
- Operates on 4 “AA” batteries for up to 70 days*
- Stores up to 140,000 single parameter readings or 35,000 for all parameters
- Logs data from 1 second to 3 hours
- Choose to be supplied with EC or EC/Turbidity sensor
- Supplied with USB cable for direct connection to Window’s compatible PC
- *All channels logging at 10 minute intervals with no averaging
HI-7609829 Basic Probe
- Digital probe that is less than 2 inches in diameter
- 3 colour-coded sensor inputs
- IP68 rating for continuous immersion in water
- Multistrand, multiconductor cable rated for 150 lbs (intermittent use)
- Available with 4, 10, or 20 meter cable
- Weighted shield protects all sensors
Cable lengths
- The probes are available with a choice of cable lengths: 4m, 10m and 20m
- DIN connection
- Logging probes can be connected directly to a PC with the HI-76982910 USB adaptor cable and HI-929829 PC application software to download log files directly.
On screen features
GPS Option
The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.
Quick Calibration
The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.
Graphing Capability
Trend graphing with sample date and time may be viewed on the display or transferred to PC.
Features:
Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
Backlit Dot Matrix LCD Display – The HI-9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.
Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Auto-sensor Recognition - The probe and meter automatically recognise the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.
Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.
Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.
GLP Data – HI-9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging – The HI-9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
Graphing Capability - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.
PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI-7698291 USB adapter and HI-929829 software.
Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C“ NiMH rechargeable batteries that provide up to 140 hours of battery life*.
Rugged thermoformed carrying case – The HI-9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.
* Without GPS or turbidity measurements
Fast Tracker™—Tag Identification System
HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labelled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.
iButton. Tags are Easy to Install
Install the optional TAGs near your sampling points for quick and easy iButton readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.
Read More
HI-9829 specification with/without GPS | ||
Temperature Compensation | Automatic from -5 to 55°C | |
Models with GPS | 12 Channel Receiver, 10m range | |
Logging memory from meter | 44,000 records | |
Logging interval | 1 second to 3 hours | |
Computer interface | USB (with HI-929829) | |
FastTracker™ TAG ID | Yes | |
Waterproof protection | IP67 | |
Environment | 0 to 50°C, RH 100% | |
Power supply | 1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter | |
Dimensions | 221 x 115 x 55mm | |
Weight | 750g | |
Maximum Probe Immersion | Depth – 20 metres |
HI-9829 parameter specifications | ||
pH Range | 0.00 to 14.00 pH | |
pH Resolution | 0.01 pH | |
pH Accuracy | ±0.02 pH | |
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
mV Range | ±600.0 mV | |
mV Resolution | 0.1 mV | |
mV accuracy | ±0.5 mV |
ORP Range | ±2000 mV | |
ORP Resolution | 0.1 mV | |
ORP Accuracy | ±1.0 mV | |
ORP Calibration | automatic at one custom point (relative mV) |
EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) | |
EC Resolution | Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm | |
EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater | |
EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) | |
TDS Resolution | Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) | |
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater | |
TDS Calibration | based on conductivity or salinity calibration |
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm | |
Resistivity Resolution | dependent on resistivity reading | |
Resistivity Calibration | based on conductivity calibration |
Salinity Range | 0.00 to 70.00 PSU | |
Salinity Resolution | 0.01 PSU | |
Salinity Accuracy | ±2% of reading or ±0.01 PSU whichever is greater | |
Salinity Calibration | based on conductivity calibration |
Seawater σ Range | 0.0 to 50.0 σt, σ0, σ15 | |
Seawater σ Resolution | 0.1 σt, σ0, σ15 | |
Seawater σ Accuracy | ±1 σt, σ0, σ15 | |
Seawater σ Calibration | based on conductivity or salinity calibration |
Ammonium-Nitrogen Range | 0.02 to 200.0 ppm Am (as NH4 +-N) | |
Ammonium-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm | |
Ammonium-Nitrogen Accuracy | ±5 % reading or 2 ppm | |
Ammonium-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) | |
Chloride Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm | |
Chloride Accuracy | ±5 % of reading or 2 ppm | |
Chloride Calibration | 1 or 2 point, 10 ppm and 100 ppm |
Nitrate-Nitrogen Range | 0.62 to 200.0 ppm Ni (as NO3 - -N) | |
Nitrate-Nitrogen Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm | |
Nitrate-Nitrogen Accuracy | ±5 % of reading or 2 ppm | |
Nitrate-Nitrogen Calibration | 1 or 2 point, 10 ppm and 100 ppm |
Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU | |
Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU | |
Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater | |
Turbidity Calibration | Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
DO Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) | |
DO Resolution | 0.1%; 0.01 ppm (mg/L) | |
DO Accuracy | 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading | |
DO Calibration | automatic one or two points at 0 and 100% or one custom point |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa | |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa | |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration | |
Atmospheric Pressure Calibration | automatic at one custom point |
Ordering Information | The HI-9829 is supplied with a HI-710140 hard carrying case, HI-7612VDC adapter, HI-7698292 probe maintenance kit, HI-929829 PC application software, HI-7698291 USB cable (PC to meter), HI-710045 power supply cable, HI-710046 cigarette lighter power cable, HI-9829-25 quick calibration solution, HI-920005 iButton with holder (5), HI-7609829-1 pH/ORP sensor, HI-7609829-2 galvanic DO sensor, HI-7609829-3 EC sensor, HI-7698290 short calibration beaker, HI-7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual. Probes selected with turbidity option will include the HI-7609829-4 EC/turbidity sensor, HI-7698293 long calibration beaker and HI-7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI-9829-16 0 FNU, HI-769829-17 20 FNU, and HI-9829-18 200 FNU. |
Spare Solutions
HI-9829-10 | 25 sachets 10ppm ammonia-nitrogen calibration solution | |
HI-9829-10/11 | 10 sachets each of 10ppm and 100ppm ammonia-nitrogen calibration solution | |
HI-9829-11 | 25 sachets 100ppm ammonia-nitrogen calibration solution | |
HI-9829-12 | 25 sachets 10ppm chloride calibration solution | |
HI-9829-12/13 | 10 sachets each of 10ppm and 100ppm chloride calibration solution | |
HI-9829-13 | 25 sachets 100ppm chloride calibration solution | |
HI-9829-14 | 25 sachets 10ppm nitrate-nitrogen calibration solution | |
HI-9829-14/15 | 10 sachets each of 10ppm and 100pm nitrate-nitrogen calibration solution | |
HI-9829-15 | 25 sachets 100ppm nitrate-nitrogen calibration solution |