The HI-9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters.

The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature.

The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use.

The HI-9829 is highly customisable and supplied with all necessary accessories, packaged in a durable carrying case.

  • Built in GPS Receiver
  • Colour Coded, field replaceable sensors
  • Waterproof protection
  • Logging – from probe to meter
  • Fast Tracker – Tag Identification system
  • Sensor Check™ - Auto-recognition of all sensors
  • GLP features – Meets good laboratory practices
  • Connectivity – PC compatible via USB
  • Help feature – On-screen user guides
  • Backlight – Backlit, graphic LCD display
  • Waterproof – waterproof casing

Meter with or without GPS

Built in GPS Receiver

  • 12 channel GPS receiver and antenna
  • Tracks location using satellites to within 30 feet
  • Latitude and longitude recorded with readings
  • Location naming for GPS coordinates
  • Distance from current location to stored location
  • HI-929829 software supplied integrates data collected with Google™ maps
  • Measurement readings including GPS coordinates
  • Date and time
  • Named locations and remarks
  • Sample number

(Google™ maps is a registered trademark of Google™, HANNA Instruments Ltd; has no affiliation with Google™).

Colour Coded, Field Replaceable Sensors

Dissolved Oxygen

  • HI-7609829-2 DO

pH

  • HI-7609829-0 pH
  • HI-7609829-1 pH/ORP

Conductivity and Turbidity

  • HI-7609829-4 EC/Turbidity

ISE

  • HI-7609829-0 Ammonium ISE
  • HI-7609829-11 Chloride ISE
  • HI-7609829-12 Nitrate ISE

Conductivity

  • HI-7609829-3 EC

Two probes to choose from (Basic or Logging)

The HI-7609829 (basic) and HI-7629829 (logging) are multiparameter probes for use with the HI-9829 portable meter. It is an option to choose which probe will be supplied with the HI-9829. By default the HI-9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.

HI-7629829 Autonomously Logging Probe

  • Same as basic probe but with logging capability
  • Logs data independent of HI-9829 meter
  • Operates on 4 “AA” batteries for up to 70 days*
  • Stores up to 140,000 single parameter readings or 35,000 for all parameters
  • Logs data from 1 second to 3 hours
  • Choose to be supplied with EC or EC/Turbidity sensor
  • Supplied with USB cable for direct connection to Window’s compatible PC

  • *All channels logging at 10 minute intervals with no averaging

HI-7609829 Basic Probe

  • Digital probe that is less than 2 inches in diameter
  • 3 colour-coded sensor inputs
  • IP68 rating for continuous immersion in water
  • Multistrand, multiconductor cable rated for 150 lbs (intermittent use)
  • Available with 4, 10, or 20 meter cable
  • Weighted shield protects all sensors

Cable lengths

  • The probes are available with a choice of cable lengths: 4m, 10m and 20m
  • DIN connection
  • Logging probes can be connected directly to a PC with the HI-76982910 USB adaptor cable and HI-929829 PC application software to download log files directly.

On screen features

GPS Option

The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.

Quick Calibration

The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.

Graphing Capability

Trend graphing with sample date and time may be viewed on the display or transferred to PC.

Features:

Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.

Backlit Dot Matrix LCD Display – The HI-9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.

Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.

Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

Auto-sensor Recognition - The probe and meter automatically recognise the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.

Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.

Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.

Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.

GLP Data – HI-9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.

Data Logging – The HI-9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.

Graphing Capability - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.

PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI-7698291 USB adapter and HI-929829 software.

Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C“ NiMH rechargeable batteries that provide up to 140 hours of battery life*.

Rugged thermoformed carrying case – The HI-9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.

* Without GPS or turbidity measurements

Fast Tracker™—Tag Identification System

HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labelled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.

iButton. Tags are Easy to Install

Install the optional TAGs near your sampling points for quick and easy iButton readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.

Read More

HI-9829 specification with/without GPS
Temperature Compensation Automatic from -5 to 55°C
Models with GPS 12 Channel Receiver, 10m range
Logging memory from meter 44,000 records
Logging interval 1 second to 3 hours
Computer interface USB (with HI-929829)
FastTracker™ TAG ID Yes
Waterproof protection IP67
Environment 0 to 50°C, RH 100%
Power supply 1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter
Dimensions 221 x 115 x 55mm
Weight 750g
Maximum Probe Immersion Depth – 20 metres
HI-9829 parameter specifications
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
mV Range ±600.0 mV
mV Resolution 0.1 mV
mV accuracy ±0.5 mV
ORP Range ±2000 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
EC Accuracy ±1% of reading or ±1 µS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Resolution Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
TDS Accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration based on conductivity or salinity calibration
Resistivity Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity Resolution dependent on resistivity reading
Resistivity Calibration based on conductivity calibration
Salinity Range 0.00 to 70.00 PSU
Salinity Resolution 0.01 PSU
Salinity Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration based on conductivity calibration
Seawater σ Range 0.0 to 50.0 σt, σ0, σ15
Seawater σ Resolution 0.1 σt, σ0, σ15
Seawater σ Accuracy ±1 σt, σ0, σ15
Seawater σ Calibration based on conductivity or salinity calibration
Ammonium-Nitrogen Range 0.02 to 200.0 ppm Am (as NH4 +-N)
Ammonium-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Ammonium-Nitrogen Accuracy ±5 % reading or 2 ppm
Ammonium-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
Chloride Range 0.6 to 200.0 ppm Cl (as Cl- )
Chloride Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Chloride Accuracy ±5 % of reading or 2 ppm
Chloride Calibration 1 or 2 point, 10 ppm and 100 ppm
Nitrate-Nitrogen Range 0.62 to 200.0 ppm Ni (as NO3 - -N)
Nitrate-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
Nitrate-Nitrogen Accuracy ±5 % of reading or 2 ppm
Nitrate-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
Turbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNU
Turbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
Turbidity Accuracy ±0.3 FNU or ±2 % of reading, whichever is greater
Turbidity Calibration Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
DO Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
DO Resolution 0.1%; 0.01 ppm (mg/L)
DO Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
DO Calibration automatic one or two points at 0 and 100% or one custom point
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration automatic at one custom point
Ordering Information The HI-9829 is supplied with a HI-710140 hard carrying case, HI-7612VDC adapter, HI-7698292 probe maintenance kit, HI-929829 PC application software, HI-7698291 USB cable (PC to meter), HI-710045 power supply cable, HI-710046 cigarette lighter power cable, HI-9829-25 quick calibration solution, HI-920005 iButton with holder (5), HI-7609829-1 pH/ORP sensor, HI-7609829-2 galvanic DO sensor, HI-7609829-3 EC sensor, HI-7698290 short calibration beaker, HI-7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual.
Probes selected with turbidity option will include the HI-7609829-4 EC/turbidity sensor, HI-7698293 long calibration beaker and HI-7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI-9829-16 0 FNU, HI-769829-17 20 FNU, and HI-9829-18 200 FNU.


Spare Solutions

HI-9829-10 25 sachets 10ppm ammonia-nitrogen calibration solution
HI-9829-10/11 10 sachets each of 10ppm and 100ppm ammonia-nitrogen calibration solution
HI-9829-11 25 sachets 100ppm ammonia-nitrogen calibration solution
HI-9829-12 25 sachets 10ppm chloride calibration solution
HI-9829-12/13 10 sachets each of 10ppm and 100ppm chloride calibration solution
HI-9829-13 25 sachets 100ppm chloride calibration solution
HI-9829-14 25 sachets 10ppm nitrate-nitrogen calibration solution
HI-9829-14/15 10 sachets each of 10ppm and 100pm nitrate-nitrogen calibration solution
HI-9829-15 25 sachets 100ppm nitrate-nitrogen calibration solution

Similar Products