+46 300 40 40 18
Order before 4pm for same day dispatch Weekdays only

Currency: EUR

Menu
product video
product video

HI-6321-02

The HI-6321 Advanced Benchtop Meter for Conductivity provides a laboratory-grade solution for measuring EC, resistivity, TDS, temperature and salinity in one instrument. This modern lab meter includes connectivity to WiFi and ethernet, five individual viewing modes including two GLP options and on-screen video and text tutorials.

Resistivity
Temperature
Conductivity & TDS
Salinity

€1,237.00 (exc.VAT)
€1,546.25 (tax incl.)
Full Description Specification Manuals Product Literature

HI-6321 Advanced Conductivity Benchtop Meter

The HI-6321 conductivity meter from Hanna Instruments is an ideal solution for laboratories, with a modern, efficient design and practical user interface for repeatable, reliable testing. Multiple efficiency features are included with the HI-6321, including practical data transfer options with WiFi, ethernet, USB stick and direct connection and easily accessible on-screen tutorials.

This research laboratory-grade EC benchtop meter is supplied with the Hanna HI-7631233 four-ring probe for the measurement of conductivity (μS/cm, mS/cm), resistivity (Ω・cm, kΩ・cm, MΩ・cm), TDS (ppm, ppt) and salinity (ppt, PSU, %). This purpose-built advanced probe makes the HI-6321 well-suited to a wide measurement range across various industrial process water applications.

The HI-7631233 includes an integral temperature sensor, allowing the measured conductivity to be adjusted to a reference temperature through the application of specialised compensation algorithms.

HI-6321 Laboratory Conductivity Meter Features

Practical, streamlined design

The HI-6000 series are streamlined meters designed to suit the requirements of modern laboratories. A practical, smaller footprint and simple design with a large, capacitive touchscreen that can be used even with gloves on make this EC meter a practical choice. The electrode arm can be swapped to either side of the meter, providing greater flexibility in placement within the lab.

Supplied with Hanna four-ring probe

The HI-6321 conductivity meter is supplied with the Hanna HI-7631233 probe for the measurement of conductivity, resistivity, TDS and salinity, with an integral temperature sensor. This purpose-built four-ring probe does not require frequent calibration and covers a comprehensive measurement range for all key parameters.

The integrated temperature sensor enables adjustment to measured conductivity through the application of one of three specialised compensation algorithms:

  • Linear: appropriate for use in measurement where the temperature coefficient of variation has the same value for all measurement temperatures
  • Standard: appropriate for use in high-purity water measurements and>1Mohm.cm resistivity measurements
  • Natural: appropriate for use in natural well, ground or surface water or any water with a similar composition (ISO 7888 standard)

Electrode holder included

A dedicated electrode holder is included with the HI-6321 EC lab meter, allowing you to securely hold your probe while measuring samples. The holder can be mounted on either side of the meter, providing flexibility in placement in the laboratory.

Reliable and accurate measurement

The HI-6321 conductivity meter is designed to be exceptionally accurate in measuring TDS, conductivity, salinity and resistivity across a wide range with the ability to measure in multiple units for each parameter:

  • TDS: TDS is both a calculated value based on the solution’s conductivity (factor x EC25) and is a conversion factor to measure EC in ppm
  • Salinity PSU: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 °C and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg water at the same temperature and pressure. Under these conditions, the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 °C.
  • Salinity PPT: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g/L and covers the 10 to 31 °C temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 °C and an approximate salinity value of 35 in seawater.
  • Salinity %: in this scale 100% salinity is equivalent to roughly 10% solids.

Flexible configuration and design

The ability to connect via WiFi and ethernet with no requirement for a PC or printer connection allows greater flexibility in where the HI-6321 can be placed in the lab. The configurable electrode arm provides further flexibility in placement, allowing the advanced meter for EC to be placed up against a wall on either side as required.

Simple-to-use interface

The HI-6321 features a user-friendly interface, with easily accessible settings for quick setup out of the box. The full-featured menu includes all of the necessary functionalities to customise the conductivity meter, including:

  • Network
  • Connect and Print
  • System
  • Custom Users
  • User Account Management
  • Info Screen
  • Log Recall
  • Log History and Sharing
  • Log Detail
  • On-Board Help

Five measurement view options

Five different measurement views are available for the HI-6321, offering a variety of data options to suit individual requirements:

  • Basic View: A simplified view including the measurement unit and measured value
  • Simple GLP View: Including displays of the latest calibration date and time, Offset value, average slope and electrode condition.
  • Full GLP View: Complete display including the electrode symbol and used buffers tray in addition to the above.
  • Graph View: A live, plotted graph of the measured value.
  • Tabulated View: Data presented in a table with measured values plus date, time and all notes made during measurement.

Extensive capacity for data

The HI-6000 series meters feature an expanded capacity of data storage, with up to 1 million data points stored at any time, inclusive of both the time and date stamps for easy filtering. Data is exported in a universal .csv file and accessible via ethernet, connection to a PC or printer or WiFi.

Visual and audible alarm system

A robust, customisable alarm system is available within the settings of the HI-6321, with options for audible and visual warnings. Correct ranges can be input directly into the alarm, activating when a measurement exceeds these predefined limits when testing.

Connect via WiFi and ethernet

Share data directly with FTP and email transfer over WiFi and ethernet, allowing .csv data from measurements to be immediately sent to local PCs and remote locations as necessary with no additional steps in external software required.

Transfer with USB A and C

The HI-6321 includes both USB C and A connection, allowing for peripherals such as a keyboard to be used with the system as well as providing connectivity to PCs and laptops. Additionally, data can be transferred via a USB memory stick in .csv format, providing immediate access to test data without needing extra software.

In-built video tutorial system

All HI-6000 series advanced meters include a comprehensive tutorial HELP functionality, providing on-screen instructions for the main functionalities of these laboratory-grade meters. Both video and text instruction are available to suit your preferred learning style.

Complete customisability for users

Create and edit custom users directly on the HI-6321, with both standard and administrator options. Administrators can manage and create accounts directly from the Account Management Screen, with customisable configurations to provide limited or full access for additional users.

FAQs

What instruments are in the HI-6000 range?

The HI-6000 range includes:

Is the HI-6321 suitable for laboratory usage?

The HI-6321 EC meter is specifically developed for use in laboratory environments across a wide range of industries and specialisations. This advanced meter is suitable for businesses with a range of industrial applications and for laboratories that provide accurate outsourced testing for their clients.

What are the key features of the HI-6321?

Some of the key features of the Hanna HI-6321 include:

  • Measures conductivity, salinity, TDS and resistivity
  • Connect via WiFi and ethernet
  • Easy-to-use interface
  • Space-saving design
  • Exceptional repeatability and accuracy

What industries is the HI-6321 suitable for?

The HI-6321 is a versatile conductivity meter that is suitable for a wide range of industries and applications. This benchtop meter is beneficial for industrial process water applications, providing accurate measurement of salinity, conductivity, resistivity and TDS.

Read More

Conductivity
 Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm;
1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm
 Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
 Accuracy ±1 % of reading (±0.01 μS/cm)
Resistivity
 Range 1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm
 Resolution 0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm
 Accuracy ±1 % of reading (±1 Ω・cm)
Total Dissolved Solids (TDS)
 Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)
 Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
 Accuracy ±1 % of reading (}0.01 ppm)
Salinity
 Range 0.00 to 42.00 PSU - Practical Scale
0.00 to 80.00 ppt - Natural Sea Water
0.0 to 400.0 % - Percent Scale
 Resolution 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale
 Accuracy ±1 % of reading
Temperature
 Range −20.0 to 120.0 °C; 253.0 to 393.0 K
 Resolution 0.1 °C; 0.1 °F; 0.1 K
 Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
Conductivity Calibration
 Calibration points Auto standard recognition / User standard, Single Point / Multi Point calibration
 Standard solutions 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm
 Reminder Disabled
Daily: 0 min. to 23 hours and 59 min.
Periodic: 1 min. to 500 days, 23 hours and 59 min.
Resistivity Calibration Uses Conductivity
Salinity Calibration 1 point for Percent Scale
Temperature Compensation Automatic or Manual
Reading
 Modes Direct
Direct/Autohold
 Stability criteria Accurate
Medium
Fast
 Sampling rate 1000 ms
EC Views
 Basic Measurement (EC, Resistivity, TDS, Salinity, Temperature)
Stability status
 Simple GLP Basic view information
Last calibration date, offset
 Full GLP Simple GLP information and calibration point details
 Table Measurements updated every second are displayed in table
 Graph (Plot) Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology)
Logging
 Type Automatic, Manual, Autohold
 Number of records 50 000 maximum per file
Stores at least 1 000 000 data points per user
 Automatic interval 1, 2, 5, 10, 30 seconds
1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
 Sample ID Incremental mode
 Export option .csv file format
Users Up to 9 users and the default administrator account
Connectivity
 USB-A 2 ports for keyboard input or USB thumb drive
 USB-C 1 port for PC connectivity and USB-C type thumb drive
 Wi-Fi & Ethernet FTP
Web server Log transfer and download
Email
 RS232 Connecting peripherals
Power supply DC adapter 100-240AC to 24VDC 2.5A
Environment 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing
Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)
Weight Approximately 1.2 kg (26.5 lbs.)
Ordering Information HI-6321 is supplied with HI-7631233 probe; HI-764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.

Similar Products