HI-706-25 Reagents for HI-706 Phosphorus High Range Colorimeter - Checker®HC

HI-706-25

The HI-706-25 are the replacement reagents for the HI-706 Phosphorus High Range Checker® HC. 

40 tests

€11.00 (exc.VAT)
€13.75 (tax incl.)
Accessories
Reference
Price
Quantity
Full Description Specification

These high quality reagents are clearly marked with the lot number and expiry date on each bottle for traceability.

The HI-706-25 is a pack of 40 reagents for use with the HI-706 Phosphorus high range checker.

The HI-706-25 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Phosphorus High Range Checker® HC. These reagents follow the Amino Acid Method in which the reaction between phosphorus and reagents causes a blue tint in the sample. By simply adding 10 drops of the first reagent to the sample, followed by the packet of the HI-706-25 reagent set, the reaction will take place and the HI-706 will determine the concentration from the colour that is produced. The results will be displayed in ppm (mg/L) of phosphorus. These reagents are designed to be used with samples that have an expected range of 0.00 to 15.00 ppm (mg/L) phosphorus.

Tip for an accurate measurement

It is important that the sample does not contain any debris.

Whenever the cuvette is placed into the measurement cell, it must be dry outside and completely free of fingerprints, oil or dirt. Wipe it thoroughly with HI-731318 or a lint-free cloth prior to insertion.

Shaking the cuvette can generate bubbles, causing higher readings. To obtain accurate measurements, remove such bubbles by swirling or by gently tapping the cuvette.

Do not let the reacted sample stand for too long after reagent is added, or accuracy will be lost.

After the reading, it is important to discard the sample immediately, otherwise the glass might become permanently stained.

Four steps. One click. Instant Readout.

1. ‘Zero’ the Checker®HC with your vial inside

2. Place a 10ml water sample into the vial and add your reagent

3. Place your vial into your Checker®HC

4. Press the button and read the results

Also available: HI-706-11 calibration set.

Read More

Packagesachets
Quantity40 tests
MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Heteropolymolybdenum Blue method. The reaction between reactive phosphorus and the reagent causes a blue tint in the sample.