Hanna HI-97713C Phosphate Low Range Portable Photometer

HI-97713C

HI-97713C kit contains an advanced portable photometer for the measurement of low range phosphate in water.

6 954 kr Exl. moms
8 692 kr (inkl. moms)
Tillbehör
Art.nr.
Pris
Kvantitet
Beskrivning Specifikation Manuals

HI-97713C kit is supplied with a meter, CAL Check cuvette A, CAL check cuvette B for phosphate LR, sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5 V AA batteries (3), cuvette wiping cloth, scissors, instrument quality certificate, instruction manual and rigid carrying case.

The HI-97713 is an advanced portable photometer for the measurement of low range phosphate in water. This meter offers a superior optical system that utilises a reference detector and narrow band interference filters for extremely fast and repeatable measurements.

Measurement method: Adaptation of the Ascorbic Acid method.

  • Range: 0.00 to 2.50 mg/L (as PO43-)
  • Advanced LED optical system – LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.
  • CAL Check™ - Validate the performance of the instrument at any time and apply a user calibration using CAL Check cuvettes made with NIST traceable standards. The CAL Check screen guides the user step-by-step through the validation process and user calibration.
  • Auto logging
  • GLP – Review of the last calibration date
  • On-screen tutorial mode with animations – the built in tutorial mode guides users step-by-step through the measurement process.
  • Waterproof and floating IP67 case
  • Auto-shut off – Automatic shut off after 15 minutes of inactivity and 30 minutes before a read measurement.
  • Battery status indicator – Indicates the amount of battery life left.
  • Built-in timer – Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.
  • Error messages – Messages on display alerting to problems including no cap, high zero, and standard too low.
  • Unit of measure – Appropriate unit of measure is displayed along with reading.

Läs mer

Range0.00 to 2.50 mg/L (as PO43-)
Resolution0.01 mg/L
Accuracy @25°C±0.04 mg/L ±4% of reading at 25°C
MethodAdaptation of the Ascorbic Acid Method
Light Sourcelight emitting diode
Bandpass filter610nm
Bandpass filter bandwidth8nm
Bandpass filter wavelength accuracy±1.0nm
Light DetectorSilicon photocell
Cuvette typeRound 24.6mm diameter (22mm inside)
Auto logging50 readings
Display128 x 64 pixel B/W LCD with backlight
Auto-offAfter 15 minutes of inactivity (30 minutes before a READ measurement)
Battery type/lifeAlkaline 1.5 V AA (3)/ >800 measurements (without backlight)
Environment0 to 50°C; 0 to 100% RH
Dimensions142.5 x 102.5 x 50.5 mm
Weight380g
Ordering informationHI-97713 is supplied with sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5V AA batteries (3), instrument quality certificate and instruction manual.
Available as a kit: HI-97713C includes photometer, CAL Check cuvette A & B for phosphate LR, sample cuvettes (2), sample caps (2), plastic stoppers (2), 1.5V AA batteries (3), cuvette wiping cloth, scissors, instrument quality certificate, instruction manual and rigid carrying case.