HI-6000-2 PH/ORP/ISE MODULE FOR HI-6000 SERIES BENCH MULTIPARAMETER
In Stock 1 Produkt Tillgänglig
HI-6000-2
The HI6000-2 module measures pH, ORP, ISE and temperature.
The HI6000-2 module measures pH, ORP , ISE and temperature with HI-6000 modular multiparameter meter system
Measurement
• Choice of Measurement Unit
• pH ( HI6000-2) – pH, mV
• ORP ( HI6000-2) – mV, Rel.mV
• ISE (HI6000-2 ) – ppt, ppm, ppb, g/L, mg/L, μg/L, mg/mL, μg/mL, M, mol/L, mmol/L, %w/v, user defined
• Reading modes:
• Direct and direct/autohold
• Known Addition, Known Subtraction, Analyte Addiiton, Analyte Subtration (HI6000-2)
Calibration
• pH calibration using
• Up to five Hanna Instruments pH buffers (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
• Up to five custom buffers
• mV calibration using a single point to calibrate offset.
• ISE calibration using up to five nominal standard values and/or up to five custom solutions (user supplied)
Recommended probes For pH measurements,
Hanna recommends the HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe for use with these modules.
HI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of high temperature (HT) glass. The double junction reference and HT glass design allow the electrode to be used in a wide variety of applications. Probe connection to the unit is secured through a galvanically isolated BNC connection.
Suitable Hanna Ion Selective Electrodes for ISE measurements.
HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.
Read Less
Läs mer
Range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH | |
Resolution | 0.1 pH; 0.01 pH; 0.001 pH | |
Accuracy | ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) | |
Temperature Compensation | Automatic or manual | |
mV | ||
Range | -2000.0 mV to 2000.0 mV | |
Resolution | 1 mV; 0.1 mV | |
Accuracy | ±0.2 mV ±1 last significant digit | |
ISE | ||
Range | 1 x 10-6 to 9.99 x 1010 concentration | |
Resolution | 1; 0.1; 0.01; 0.001 concentration | |
Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) | |
Calibration | Automatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards | |
Temperature | ||
Range | -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K | |
Resolution | 0.1 °C / 0.1 °F / 0.1 K | |
Accuracy | ±0.2 °C / ±0.4 °F / ±0.2 K | |
Relative mV offset range | ±2000.0 mV | |
pH Calibration | ||
Calibration points | Up to 5 | |
Type | Automatic; Semiautomatic; Manual | |
Standard buffers | Hanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 | |
Custom buffers | Up to 5 | |
Custom group | Up to 5 | |
1st calibration point | Offset or Points (user setting) | |
Temperature User Calibration | Single point, adjustable; Isopotential point: -2.000 to 20.000pH |