- Ny




HI-2621 PH AND ORP BENCHTOP METER WITH DATA LOGGING
HI-2621
HI-2621 enables fast, accurate measurements of pH, ORP, and temperature utilising Hanna’s HI-11310 digital pH electrode and HI-36180 Digital ORP probe. Ideal for laboratories, classrooms and general industry.
The HI-2621 architecture brings together Hanna’s visionary design capabilities, integrated production, and world class research and development.
HI-2621 pH and ORP Benchtop meter with Data Logging
HI-2621 benchtop meter enables fast, accurate pH and ORP measurements utilising the Hanna Instruments digital electrode / probes for pH (HI-11310), ORP (HI-36180). Each digital electrode / probe has a unique serial number and the parameter that it measures is automatically identified by the meter.
Once connected, the single sensor or sensors are ready to measure the parameter along with temperature.
The intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer.
he
The HI-2621 offers a Basic Mode that streamlines measurement configuration and is useful for routine applications as well as a Standard Operating Mode, where all features and capabilities are enabled.
The compact meter (and probe) can be used in classrooms and general industry or used as laboratory instrumentation.
The meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle.
Main feature points
- Automatic parameter recognition
- pH/ORP choice of measurement units: pH, mV;
- CAL Check indicators
- Sensor Check indicators
- Basic mode for simplified operation
- Dedicated GLP key
- GLP data included with logged data
- Simplified data transfer to a PC
- Internal clock and date
Key Features
Digital probe input - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.
Clear, full text readout
- The HI-2621 presents clear, detailed text prompts at the bottom section of the screen.
Two operating modes - HI-2621 can be used in Standard or Basic Operating Modes (pH and EC only). Standard Mode enables all features while Basic Mode displays a simplified screen and features —ideal for routine measurements.
Data logging - The HI-2621 provides ample data storage capacity, allowing you to save up to 1000 log records. Each data set comprehensively includes readings, GLP information, as well as date and time stamps.
GLP - The sensor retains data from the most recent calibration, including date, time, and buffers utilised. When connected to the HI-2621, this GLP information is automatically transferred.
CAL Check - Hanna’s exclusive CAL Check feature analyses the pH electrode’s response in calibration buffers to detect potential issues such as contaminated solutions or dirty electrodes. Upon completing calibration, indicators reflecting the probe’s condition—based on its offset and slope characteristics—are displayed on the measurement screen.
Sensor Check (using HI-11311 and HI-12301 pH probes only) - When paired with compatible Hanna electrodes featuring a matching pin, HI-2600 continuously monitors the impedance of the pH measuring electrode, providing real-time alerts in case of glass breakage. During calibration, Sensor Check displays the junction condition, by evaluating the reference junction resistance.
ORP measurement - Measure ORP (REDOX) in mV units by using a compatible ORP sensor.
Capacitive touch keypad - HI-2621 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.
Easy to read LCD - HI-2621 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry.
USB-C port for charging and data transfer - The HI-2621 features a streamlined USB-C port that facilitates transferring data to your computer.
What's included:
- HI-11310 pH digital electrode
- HI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached
- pH calibration kit: pH 4 buffer solution (2 sachets); pH 7 buffer solution (4 sachets); pH 10 buffer solution sachets (2 sachets)
- Electrode cleaning solution (2 sachets)
- HI-920018 - 1.5m USB-C to USB-C cable
- USB-C power adapter
- Instrument quality certificate
- Probe / electrode quality certificate
- Battery safety insert
- Quick reference guide with QR code for instruction manual download
Warranty - Meter has 2 years. 6 months from date of purchase for electrodes and probes
More electrodes to buy separately
Electrodes
- HI-10530 Triple ceramic, double junction, glass body, refillable pH electrode with conical tip and temperature sensor
- HI-10430 Triple ceramic, double junction, glass body, refillable pH electrode with temperature sensor
- HI-11310 Glass body, double junction, refillable pH/temperature electrode
- HI-11311 Glass body, double junction, refillable pH/ temperature electrode with enhanced diagnostics
- HI-12300 Plastic body, double junction, gel filled, non-refillable pH / temperature electrode
- HI-12301 Plastic body, double junction, gel filled, non-refillable pH/temperature electrode with enhanced diagnostics
- HI-36180 Glass body, double junction, refillable ORP/temperature probe
More solutions to buy separately
pH solutions – 500mL (other sizes available)
- HI-7001L pH 1.68 buffer solution, 500 mL
- HI-7004L pH 4.01 buffer solution, 500 mL
- HI-7006L pH 6.86 buffer solution, 500 mL
- HI-7007L pH 7.01 buffer solution, 500 mL
- HI-7009L pH 9.18 buffer solution, 500 mL
- HI-7010L pH 10.01 buffer solution, 500 mL
ORP solutions
- HI-7021L ORP test solution, 240 mV @ 25 °C, 500 mL
- HI-7022L ORP test solution, 470 mV @ 25 °C, 500 mL
- HI-7091L Reducing Pretreatment Solution, 500 mL bottle +14 g (set)
- HI-7092L Oxidizing Pretreatment Solution, 500 mL bottle
pH electrode maintenance solutions
- HI-70300L Storage solution, 500 mL
- HI-70000P Electrode rinse sachets (25 sachets × 20 mL)
- HI-7061L General cleaning solution, 500 mL
Other useful accessories
- HI-764026 Electrode holder for HI-2600 family
Models in the series
HI-2600 pH, EC, DO Benchtop Meter with Data Logging
HI-2620 pH and ORP Benchtop Meter
HI-2621 pH and ORP Benchtop Meter with Data Logging
HI-2630 EC & TDS Benchtop Meter
HI-2631 EC, TDS and Salinity Benchtop Meter with Data Logging
Läs mer
| pH - using HI-11310 pH electrode | ||
| pH Range | basic mode: -2.00 to 16.00 pH; standard mode: -2.000 to 16.000 pH | |
| Resolution | basic mode: 0.01 pH; standard mode: 0.001 pH | |
| Accuracy (@25°C) | basic mode: ±0.01 pH; standard mode: ±0.002 pH | |
| Calibration | Basic Mode: Automatic, up to three points, option to select 5 standard buffers. Standard mode: Automatic, up to five point calibration, 7 standard buffers available and two custom buffers. |
|
| Temperature Compensation | Automatic, -5.0 to 100.0°C (using integral temperature sensor) | |
| Logging | Up to 1000 (in Standard Mode) records organised in: • Manual log-on-demand, maximum 200 logs • Manual log-on-stability, maximum 200 logs • Interval logging in Standard Mode |
|
| mV - using HI-11310 pH electrode | ||
| mV pH Range | ±1000 mV | |
| Resolution | 0.1 mV | |
| Accuracy (@25°C) | ±0.2 mV | |
| ORP – using HI-36180 ORP electrode | ||
| ORP Range | ±2000.0 mV | |
| Resolution | 0.1 mV | |
| Accuracy (@25°C) | ±0.2 mV (±999.9mV); ±1mV (±2000mV) | |
| Calibration | Single point offset | |
| Temperature Compensation | Automatic, using integral temperature sensor -5.0 to 100.0°C | |
| Logging | Up to 1000 in Standard Mode records organised in: • Manual log-on-demand, maximum 200 logs • Manual log-on-stability, maximum 200 logs • Interval logging in Standard Mode |
|
| Temperature | ||
| Temperature Range | -20.0 to 120.0 °C (temp limits reduced to probe limits) | |
| Resolution | 0.1°C | |
| Accuracy | ±0.5°C | |
| Additional Specifications: | ||
| Probe | HI-11310 digital glass bodied pH electrode with 3.5mm connector and 1m cable | |
| PC Interface | USB-C | |
| Power supply | USB Type C (5 VDC; 500mA) | |
| Environment | 0 to 50˚C; Maximum 95% RH non-condensing | |
| Dimensions | 205 x 160 x 77 mm | |
| Weight | Approximately 0.85 kg | |
| Ordering Information | HI-2621 pH/ORP benchtop meter includes HI-11310 glass body refillable pH electrode, pH 4 buffer solution sachets (2), pH 7 buffer solution sachets (4), pH 10 buffer solution sachets (2), electrode cleaning solution sachets (2), electrode holder, 1.5 m USB-C to C USB-C cable. |