+46 300 40 40 18
Beställ innan kl 16.00 för leverans dagen efter. Endast vardagar

Currency: SEK

Menu
Hanna HI-801-02 Iris Spectrophotometer
product video
Hanna Hi-801-02 iris Spectrophotometer
Hanna HI-801-02 Iris Spectrophotometer
product video
Hanna Hi-801-02 iris Spectrophotometer

HI-801-02

The HI-801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.

Customise your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.

precise wavelength between 340 nm to 900 nm
Wavelength Accuracy ±1.5 nm

37 423 kr Exl. moms
46 779 kr (inkl. moms)
Beskrivning Specifikation Product Literature
  • iris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more.
  • Results are consistent and accurate regardless of throughput with the high quality and uniquely designed optics system.
  • Customisation options include multiple cuvette shapes and sizes, custom calibration curves, and methods.

Superior design for superior results

iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.

With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.

No need for measurement conversions

Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.

Pre-programmed methods with the option to expand

iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.

Customise your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.

Easily access your favourite methods directly from the home screen to save time.

Built in timers make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.

Worry free replacements

iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.

Designed for dynamic environments

iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.

Quality data without the hassle

Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.

Sort and share your data

Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that is best for you.

Menu navigation that makes sense

Quickly navigate between screens with custom keys, and access your favourite methods directly from the home screen with our “favourite methods” feature.

All of your important information is easily visible

With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.

Zero resistance with a capacitive touch pad

Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognises key touches even through gloves.

Change sample size easily

With its universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.

Läs mer

Wavelength Range 340 to 900 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm
Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, °f, °e, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, °dH, meq/kg or no measurement unit)
Wavelength Selection automatic, based on the selected method (editable for user methods only)
Light Source tungsten halogen lamp
Optical System split beam sample and reference light detectors
Wavelength Calibration Internal, automatic at power-on, visual feedback
Stray Light <0.1 t=" at=" 340=" nm=" with=" nano=" sub=">2
Spectral bandwidth 5 nm (full width at half maximum)
Sample Cell 16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection)
Programs (Factory/User) Up to 150 factory (85 pre-loaded); up to 100 user developed
Data Points Stored Up to 9999 measured values
Export Capability .csv file format, .pdf file format
Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device)
Battery Type / Life 3000 measurements or 8 hours
Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Dimensions 155 x 205 x 322 mm
Weight 3 kg (6.6 lbs)
Ordering Information HI-801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.

ABSORBANCE
 Range 0.000 to 3.000 Abs
 Resolution 0.001 Abs
 Accuracy (@25°C) 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
ALKALINITY
 Range 0 to 500 mg/L (as CaCO3 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±5% of reading
 Method Colorimetric Method
 Wavelength 610 nm
 Reagent Code HI-775-26
ALKALINITY, MARINE
 Range 0 to 300 mg/L (as CaCO3 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±5% of reading
 Method Colorimetric Method
 Wavelength 610 nm
 Reagent Code HI-755-26
ALUMINIUM
 Range 0.00 to 1.00 mg/L (as Al3+)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±4% of reading
 Method Adaptation of the aluminon method
 Wavelength 525 nm
 Reagent Code HI-93712-01
AMMONIA, LOW RANGE
 Range 0.00 to 3.00 mg/L (as NH3 -N)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±4% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
 Wavelength 420 nm
 Reagent Code HI-93700-01
AMMONIA, MEDIUM RANGE
 Range 0.00 to10.00 mg/L (as NH3 -N)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L ±5% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method
 Wavelength 420 nm
 Reagent Code HI-93715-01
AMMONIA, HIGH RANGE
 Range 0.0 to 100.0 mg/L (as NH3 -N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±5% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method
 Wavelength 420 nm
 Reagent Code HI-93733-01
BROMINE
 Range 0.00 to 8.00 mg/L (as Br2 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.08 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
 Wavelength 525 nm
 Reagent Code HI-93716-01
CALCIUM
 Range 0 to 400 mg/L (as Ca2+)
 Resolution 1 mg/L
 Accuracy (@25°C) ±10 mg/L ±5% of reading
 Method Adaptation of the Oxalate method
 Wavelength 466nm
 Reagent Code HI-937521-01
CALCIUM, MARINE
 Range 200 to 600 mg/L (as Ca2+)
 Resolution 1 mg/L
 Accuracy (@25°C) ±6% of reading
 Method Adaptation of the Zincon method
 Wavelength 610 nm
 Reagent Code HI-758-26
CHEMICAL OXYGEN DEMAND
 LOW RANGE
 Range 0 to 150 mg/L (as O2 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L or ±4% of reading
 Method Adaptation of the USEPA 410.4
 Wavelength 420 nm
 Reagent Code HI-93754A-25
CHEMICAL OXYGEN DEMAND
 MEDIUM RANGE
 Range 0 to 1500 mg/L (as O2)
 Resolution 1 mg/L
 Accuracy (@25°C) ±15 mg/L or ±4% of reading
 Method Adaptation of the USEPA 410.4
 Wavelength 610 nm
 Reagent Code HI-93754B-25
CHEMICAL OXYGEN DEMAND
 HIGH RANGE
 Range 0 to 15000 mg/L (as O2 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±150 mg/L or ±2% of reading
 Method Adaptation of the USEPA 410.4
 Wavelength 610 nm
 Reagent Code HI-93754C-25
CHLORIDE
 Range 0.0 to 20.0 mg/L (as Cl)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±6% of reading
 Method Adaptation of the mercury(II) thiocyanate method
 Wavelength 466 nm
 Reagent Code HI-93753-01
CHLORINE DIOXIDE
 Range 0.00 to 2.00 mg/L (as ClO2 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.10 mg/L ±5% of reading
 Method Adaptation of the Chlorophenol Red method
 Wavelength 575 nm
 Reagent Code HI-93738-01
CHLORINE, FREE ULTRA LOW RANGE
 Range 0.000 to 0.500 mg/L (as Cl2 )
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.020 mg/L ±3% of reading
 Method Adaptation of the Standard Method 4500-Cl G
 Wavelength 525 nm
 Reagent Code HI-95762-01
CHLORINE, FREE LOW RANGE
 Range 0.00 to 5.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93701-01
CHLORINE, FREE HIGH RANGE
 Range 0.00 to 10.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93734-01
CHLORINE, TOTAL ULTRA LOW RANGE
 Range 0.000 to 0.500 mg/L (as Cl2 )
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.020 mg/L ±3% of reading
 Method Adaptation of the EPA recommended Method 330.5
 Wavelength 525 nm
 Reagent Code HI-95761-01
CHLORINE, TOTAL LOW RANGE
 Range 0.00 to 5.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93711-01
CHLORINE, TOTAL HIGH RANGE
 Range 0.00 to 10.00 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the EPA DPD method 330.5
 Wavelength 525 nm
 Reagent Code HI-93734-01
CHLORINE, TOTAL ULTRA HIGH RANGE
 Range 0 to 500 mg/L (as Cl2)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl
 Wavelength 525 nm
 Reagent Code HI-95771-01
CHROMIUM (VI), LOW RANGE
 Range 0 to 300 µg/L (as Cr(VI))
 Resolution 1 µg/L
 Accuracy (@25°C) ±10 µg/L ±4% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method
 Wavelength 525 nm
 Reagent Code HI-93749-01
CHROMIUM (VI), HIGH RANGE
 Range 0 to 1000 µg/L (as Cr(VI))
 Resolution 1 µg/L
 Accuracy (@25°C) ±5 µg/L ±4% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method
 Wavelength 525 nm
 Reagent Code HI-93723-01
COLOUR OF WATER
 Range 0 to 500 PCU (Platinum Cobalt Units)
 Resolution 1 PCU
 Accuracy (@25°C) ±10 PCU ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
 Wavelength 420 nm
 Reagent Code
COPPER, LOW RANGE
 Range 0.000 to 1.500 mg/L (as Cu)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.010 mg/L ±5% of reading
 Method Adaptation of the EPA method
 Wavelength 575 nm
 Reagent Code HI-95747-01
COPPER, HIGH RANGE
 Range 0.00 to 5.00 mg/L (as Cu)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.02 mg/L ±4% of reading
 Method Adaptation of the EPA method
 Wavelength 575 nm
 Reagent Code HI-93702-01
CYANIDE
 Range 0.000 to 0.200 mg/L (as CN-)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.005 mg/L ±3% of reading
 Method Pyridine-Pyrazalone
 Wavelength 610 nm
 Reagent Code HI-93714-01
CYANURIC ACID
 Range 0 to 100 mg/L (as CYA)
 Resolution 1 mg/L
 Accuracy (@25°C) ±1 mg/L ±15% of reading
 Method Adaptation of the turbidimetric method
 Wavelength 525 nm
 Reagent Code HI-93722-01
FLUORIDE, LOW RANGE
 Range 0.00 to 2.00 mg/L (as F)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
 Wavelength 575 nm
 Reagent Code HI-93729-01
FLUORIDE, HIGH RANGE
 Range 0.0 to 20.0 mg/L (as F)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
 Wavelength 575 nm
 Reagent Code HI-93739-01
HARDNESS, CALCIUM
 Range 0.00 to 2.70 mg/L (as CaCO3)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.11 mg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
 Wavelength 525 nm
 Reagent Code HI-93720-01
HARDNESS, MAGNESIUM
 Range 0.00 to 2.00 mg/L (as CaCO3)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.11 mg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
 Wavelength 525 nm
 Reagent Code HI-93719-01
HARDNESS, TOTAL LOW RANGE
 Range 0.00 to 250 mg/L (as CaCO3)
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±4% of reading
 Method Adaptation of the EPA recommended method 130.1
 Wavelength 466 nm
 Reagent Code HI-93735-00
HARDNESS, TOTAL MEDIUM RANGE
 Range 200 to 500 mg/L (as CaCO3)
 Resolution 1 mg/L
 Accuracy (@25°C) ±7 mg/L ±3% of reading
 Method Adaptation of the EPA recommended method 130.1
 Wavelength 466 nm
 Reagent Code HI-93735-01
HARDNESS, TOTAL HIGH RANGE
 Range 400 to 750 mg/L (as CaCO3)
 Resolution 1 mg/L
 Accuracy (@25°C) ±10 mg/L ±2% of reading
 Method Adaptation of the EPA recommended method 130.1
 Wavelength 466 nm
 Reagent Code HI-93735-02
HYDRAZINE
 Range 0 to 400 µg/L (as N2H4 )
 Resolution 1 µg/L
 Accuracy (@25°C) ±4% of full scale reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
 Wavelength 466 nm
 Reagent Code HI-93704-01
IODINE
 Range 0.0 to 12.5 mg/L (as I2)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.1 mg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
 Wavelength 525 nm
 Reagent Code HI-93718-01
IRON, LOW RANGE
 Range 0.000 to 1.600 mg/L (as Fe)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.010 mg/L ±8% of reading
 Method Adaptation of the TPTZ Method
 Wavelength 575 nm
 Reagent Code HI-93746-01
IRON, HIGH RANGE
 Range 0.00 to 5.00 mg/L (as Fe)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±2% of reading
 Method Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters
 Wavelength 525 nm
 Reagent Code HI-93721-01
MAGNESIUM
 Range 0 to 150 mg/L (as Mg2+)
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±3% of reading
 Method Adaptation of the Calmagite method
 Wavelength 466 nm
 Reagent Code HI-937520-01
MANGANESE, LOW RANGE
 Range 0 to 300 µg/L (as Mn)
 Resolution 1 µg/L
 Accuracy (@25°C) ±10 µg/L ±3% of reading
 Method Adaptation of the PAN Method
 Wavelength 575 nm
 Reagent Code HI-93748-01
MANGANESE, HIGH RANGE
 Range 0.0 to 20.0 mg/L (as Mn)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.2 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method
 Wavelength 525 nm
 Reagent Code HI-93709-01
MAPLE SYRUP
 Range 0.00 to 100.00 %T
 Resolution 0.01 %T
 Accuracy (@25°C) ±3% of reading
 Method Direct measure
 Wavelength 560 nm
 Reagent Code HI-93703-57
MOLYBDENUM
 Range 0.0 to 40.0 mg/L (as Mo6+)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.3 mg/L ±5% of reading
 Method Adaptation of the mercaptoacetic acid method
 Wavelength 420 nm
 Reagent Code HI-93730-01
NICKEL, LOW RANGE
 Range 0.000 to 1.000 mg/L (as Ni)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.010 mg/L ±7% of reading
 Method Adaptation of the PAN method
 Wavelength 575 nm
 Reagent Code HI-93740-01
NICKEL, HIGH RANGE
 Range 0.00 to 7.00 g/L (as Ni)
 Resolution 0.01 g/L
 Accuracy (@25°C) ±0.07g/L ±4% of reading
 Method Adaptation of the photometric method
 Wavelength 575 nm
 Reagent Code HI-93726-01
NITRATE
 Range 0.0 to 30.0 mg/L (as NO3 - N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L ±10% of reading
 Method Adaptation of the cadmium reduction method
 Wavelength 525 nm
 Reagent Code HI-93728-01
NITRATE, CHROMOTROPIC ACID
 Range 0.0 to 30.0 mg/L (as NO3 - N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±1.0 mg/L ±3% of reading
 Method Chromotropic acid method
 Wavelength 410 nm
 Reagent Code HI-93766-50
NITRITE MARINE
 ULTRA LOW RANGE
 Range 0 to 200 µg/L (as N02-N)
 Resolution 1 µg/L
 Accuracy (@25°C) ±10 µg/L ±4% of reading
 Method Adaptation of the EPA Diazotization method 354.1
 Wavelength 466nm
 Reagent Code HI-764-25
NITRITE, LOW RANGE
 Range 0 to 600 µg/L (as N02-N)
 Resolution 1 µg/L
 Accuracy (@25°C) ±20 µg/L ±4% of reading
 Method Adaptation of the EPA Diazotization method 354.1
 Wavelength 466nm
 Reagent Code HI-93707-01
NITRITE, HIGH RANGE
 Range 0 to 150 mg/L (as NO2-)
 Resolution 1 mg/L
 Accuracy (@25°C) ±4 mg/L ±4% of reading
 Method Adaptation of the Ferrous Sulphate method
 Wavelength 575 nm
 Reagent Code HI-93708-01
NITROGEN, TOTAL LOW RANGE
 Range 0.0 to 25.0 mg/L (as N)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±1.0 mg/L or ±5% of reading
 Method Chromotropic acid method
 Wavelength 420 nm
 Reagent Code HI-93767A-50
NITROGEN, TOTAL HIGH RANGE
 Range 10 TO 150 mg/L (as N)
 Resolution 1 mg/L
 Accuracy (@25°C) ±3 mg/L or ±4% of reading
 Method Chromotropic acid method
 Wavelength 420 nm
 Reagent Code HI-93767b-50
OXYGEN, DISSOLVED
 Range 0.0 to 10.0 mg/L (as O2)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.4 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
 Wavelength 420 nm
 Reagent Code HI-93732-01
OXYGEN SCAVENGERS
 (CARBOHYDRAZIDE)
 Range 0.00 to 1.50 mg/L (as Carbohydrazide)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.02 mg/L ±3% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OXYGEN SCAVENGERS
 (DIETHYLHYDROXYLAMINE)(DEHA)
 Range 0 to 1000 µg/L (as DEHA)
 Resolution 1 µg/L
 Accuracy (@25°C) ±5 µg/L ±5% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OXYGEN SCAVENGERS
 (HYDROQUINONE)
 Range 0.00 to 2.50 mg/L (as Hydroquinone)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±3% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OXYGEN SCAVENGERS
 (ISO-ASCORBIC ACID)
 Range 0.00 to 4.50 mg/L (as Iso-ascorbic acid)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the iron reduction method
 Wavelength 575 nm
 Reagent Code HI-96773-01
OZONE
 Range 0.00 to 2.00 mg/L (as O3 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.02 mg/L ±3% of reading
 Method Colorimetric DPD Method
 Wavelength 525 nm
 Reagent Code HI-93757-01
pH
 Range 6.5 to 8.5 pH
 Resolution 0.1pH
 Accuracy (@25°C) ±0.1 pH
 Method Adaptation of the Phenol Red method
 Wavelength 525 nm
 Reagent Code HI-93710-01
PHOSPHORUS
 MARINE ULTRA LOW RANGE
 Range 0 to 200 µg/L (as P)
 Resolution 1 µg/L
 Accuracy (@25°C) ±5 µg/L ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method
 Wavelength 610 nm
 Reagent Code HI-736-25
PHOSPHATE, LOW RANGE
 Range 0.00 to 2.50 mg/L (as PO4 3-)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±4% of reading
 Method Adaptation of the Ascorbic Acid method
 Wavelength 610 nm
 Reagent Code HI-93713-01
PHOSPHATE, HIGH RANGE
 Range 0.0 to 30.0 mg/L (as PO4 3-)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±1.0 mg/L ±4% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method
 Wavelength 525 nm
 Reagent Code HI-93717-01
PHOSPHORUS
 REACTIVE LOW RANGE
 Range 0.00 to 1.60 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±4% of reading
 Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
 Wavelength 610 nm
 Reagent Code HI-93758A-50
PHOSPHORUS
 REACTIVE HIGH RANGE
 Range 0.0 to 32.6 mg/L (as P)
 Resolution 0.1 mg/L
 Accuracy (@25°C) ±0.5 mg/L or ±4% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method
 Wavelength 420 nm
 Reagent Code HI-93763A-50
PHOSPHORUS, ACID HYDROLYZABLE
 Range 0.00 to 1.60 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±5% of reading
 Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
 Wavelength 610 nm
 Reagent Code HI-93758B-50
PHOSPHORUS
 TOTAL LOW RANGE
 Range 0.00 to 1.15 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±6% of reading
 Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
 Wavelength 610 nm
 Reagent Code HI-93758c-50
PHOSPHORUS
 TOTAL HIGH RANGE
 Range 0.00 to 32.6 mg/L (as P)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.05 mg/L or ±5% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method
 Wavelength 420 nm
 Reagent Code HI-93763B-50
POTASSIUM, LOW RANGE
 Range 0.0 to 20.0 mg/L (as K)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±2 mg/L ±7% of reading
 Method Adaptation of the Turbidimetric Tetraphenylborate method
 Wavelength 466 nm
 Reagent Code HI-93750-01
POTASSIUM, MEDIUM RANGE
 Range 10 to 100 mg/L (as K)
 Resolution 1 mg/L
 Accuracy (@25°C) ±10 mg/L ±7% of reading
 Method Adaptation of the Turbidimetric Tetraphenylborate method
 Wavelength 466 nm
 Reagent Code HI-93750-01
POTASSIUM, HIGH RANGE
 Range 20 to 200 mg/L (as K)
 Resolution 1 mg/L
 Accuracy (@25°C) ±20 mg/L ±7% of reading
 Method Adaptation of the Turbidimetric Tetraphenylborate method
 Wavelength 466 nm
 Reagent Code HI-93750-01
SILICA, LOW RANGE
 Range 0.00 to 2.00 mg/L (as SiO2 )
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method
 Wavelength 610 nm
 Reagent Code HI-93750-01
SILICA, HIGH RANGE
 Range 0 to 200 mg/L (as SiO2 )
 Resolution 1 mg/L
 Accuracy (@25°C) ±1 mg/L ±5% of reading
 Method Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2
 Wavelength 466 nm
 Reagent Code HI-96770-01
SILVER
 Range 0.000 to 1.000 mg/L (as Ag)
 Resolution 0.001 mg/L
 Accuracy (@25°C) ±0.020 mg/L ±5% of reading
 Method Adaptation of the PAN method
 Wavelength 575 nm
 Reagent Code HI-93737-01
SULPHATE
 Range 0 to 150 mg/L (as SO42-)
 Resolution 1 mg/L
 Accuracy (@25°C) ±5 mg/L ±3% of reading
 Method Sulphate is precipitated with barium chloride crystals
 Wavelength 466 nm
 Reagent Code HI-93751-01
SURFACTANTS, ANIONIC
 Range 0.00 to 3.50 mg/L (as SDBS)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.04 mg/L ±3% of reading
 Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
 Wavelength 610 nm
 Reagent Code HI-95769-01
ZINC
 Range 0.00 to 3.00 mg/L (as Zn)
 Resolution 0.01 mg/L
 Accuracy (@25°C) ±0.03 mg/L ±3% of reading
 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
 Wavelength 575 nm
 Reagent Code HI-93731-01