HI-93551 K, J & T Thermocouple Thermometer

HI-93551

This instrument offers the ability to take temperature measurements with different types of thermocouples and are equipped with a single button that switches between k-type, j-type or t-type thermocouples.

Use with K-type thermocouples
2 year manufacturers' warranty

7 510.28 kr Exl. moms
9 387.85 kr (inkl. moms)
Beskrivning Specifikation Manuals

The hold button freezes the display to allow the user time to record readings. the CLR button restarts the evaluation of high and low values.

These thermometers display the current temperature along with the high and low extremes achieved during measurement.

For high accuracy, the HI-93551N features a CAL button to allow the operator a simple one-point calibration in an ice bath at 0°C when probe interchange occurs.

The instruments are equipped with BEPS (Battery Error Prevention System), which alerts the user in the event that low battery power could adversely affect readings.

  • HOLD - hold function
  • Battery indicator - battery life indicator at startup
  • Waterproof - waterproof casing

K-type thermocouple probes should be ordered separately to meet your specific application.

  • HI-766C - penetration, stainless steel K-type thermocouple temperature probe wtih 1m cable.
  • HI-766D - air/gas, stainless steel K-type thermocouple temperature probe with 1m cable.
  • HI-766E1 - General purpose/penetration, stainless steel K-type thermocouple temperature probe with 1m cable.

Läs mer

Range - K -200.0 to 999.9°C; 1000 to 1371°C;
-328.0 to 999.9°F; 1000 to 2500°F
    J -200.0 to 999.9°C; -328.0 to 999.9°F; 1000 to 1832°F
    T -200.0 to 400.0°C; -328.0 to 752.0°F
Resolution - K 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C);
0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F);
0.3°F (-328.0 to 250.0°F); 1°F (1000 to 2500°F)
    J 0.1°C (-200.0 to 999.9°C);
0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to 150.0°F); 1°F (1000 to 1832°F)
    T 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C);
0.1°F (0.0 to 752.0°F); 0.2°F (-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F)
Accuracy ±0.5°C (-100.0 to 999.9°C); ±1°C (outside);
±1°F (-148.0 to 999.9°F); ±1.5° (outside);
(for 1 year, excluding probe error)
Probe K-thermocouple type, HI 766 series (not included)
CAL Button NO
Battery Type / Life 3 x 1.5V AA / approx. 500 hours of continuous use (with backlight off);
auto-off after 60 minutes of non-use (can be disabled)
Environment -10 to 50°C (14 to 122°F); RH max 100%
Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4")
Weight 235 g (8.3 oz.)