HI-4007 Chloride Half-Cell ISE

HI-4007

The HI-4007 is a solid state, half-cell ion selective electrode (ISE) for the determination of chloride (Cl-) in solution.

Solid state sensor
Klorid
6 months warranty

8 740.51 kr Exl. moms
10 925.64 kr (inkl. moms)
Tillbehör
Art.nr.
Pris
Kvantitet
Beskrivning Specifikation

The silver chloride sensing pellet produces a potential change due to the chloride ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within an epoxy body.

The HI-4007 is ideal for a variety of applications in food and beverages, agriculture, and water treatment.

  • Solid state sensor
  • Detection from 1.8 to 35,500 mg/L Cl-
  • For use with HI-5315 reference half-cell

The HI-4007 chloride ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed silver chloride sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.

Hanna’s solid state half-cell ISEs are designed for use with the HI-5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.

For the HI-4007 to measure chloride accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free chloride ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI-4007 chloride solid state ISE can measure from 50µM (1.8 mg/L) to 1M (35,500 mg/L).

Läs mer

ParameterChloride
TypeSolid-state; Half-cell
Measurement Range1M to 5X 10-5M 35000 to 1.8 ppm
Optimum pH Range2 to 11
Temperature Range0 to 80°C
Approximate Slope-57
Body O.D.12 mm
Insertion Length120 mm
Body MaterialEpoxy
Cable1m coaxial
ConnectorBNC
Possible ApplicationsDetermination of free chloride ions in emulsified food products, beverages, plants, soils and as an indicator for titration