HI-763093
When used with the HI-98199 this electrode allows for the measurement of conductivity, TDS (total dissolved solids), Resistivity, Salinity, seawater σ, and temperature.
EC
Beskrivning
Specifikation
Manuals
Skriv ut
Beskrivning
Specifikation
Manuals
When used with the HI-98199 Digital meter:
- Single-point calibration from six standards
- Temperature compensation Automatic Temperature Compensation
- Configurable temperature coefficient range from 0.00 to 6.00%/°C
- Choice of reference temperatures at 20 or 25°C
- Absolute conductivity can be displayed along with the temperature compensated value
Auto-ranging
Salinity readings Practical Salinity Scale (PSU) based on conductivity calibration
Läs mer
EC | ||
Range | 0 to 200 mS/cm | |
Resolution | manual: 1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 μS/cm from 0 to 9999 μS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 200.0 mS/cm | |
Accuracy | ±1.5% of reading or ±2 μS/cm whichever is greater | |
Calibration | Automatic single point, with six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point | |
TDS | ||
Range | 0.0 to 200.0 ppt (g/L) (the maximum value depends on the TDS factor) | |
Resolution | manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 200.0 ppt (g/L) | |
Accuracy | ±1% of reading or ±1 ppm (mg/L) whichever is greater | |
Calibration | based on conductivity calibration | |
Resistivity | ||
Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm | |
Resolution | 1 Ω•cm; 0.1 kΩ•cm; 0.0001 MΩ•cm | |
Calibration | based on conductivity calibration | |
Salinity | ||
Range | 0.00 to 70.00 PSU | |
Resolution | 0.01 PSU | |
Accuracy | ±2% of reading or ±0.01 PSU whichever is greater | |
Calibration | based on conductivity calibration | |
Seawater σ | ||
Range | 0.0 to 50.0 σt, σ₀, σ₁₅ | |
Resolution | 0.1 σt, σ₀, σ₁₅ | |
Accuracy | ±1 σt, σ₀, σ₁₅ | |
Calibration | based on conductivity calibration |