Hanna HI-1285 Spare Electrodes

In Stock 11 objekt Tillgänglig

HI-1285

Spare multi-pin pH/EC electrode with temperature sensor, cloth junction, gel-filled, 7-pole; 2 m (6.6') cable, for greenhouses, hydroponics, environmental monitoring, water treatment, boilers and cooling towers.

1 684 kr Exl. moms
2 105 kr (inkl. moms)
Tillbehör
Art.nr.
Pris
Kvantitet
Beskrivning Specifikation

The HI-1285 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The pH portion of this probe is constructed with a cloth junction, maintenance-free polymer gel electrolyte, and a low-temperature glass sensing bulb. The EC/TDS portion of this probe utilises two stainless steel pins for an amperometric determination of conductivity and total dissolved solids. A built-in temperature sensor ensures that both pH and EC/TDS readings are compensated for temperature variations in both standards and samples. The design consideration for the HI-1285 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, and boilers and cooling towers.

  • Pre-amplified pH electrode
  • Amperometric EC/TDS sensor
  • Built-in temperature sensor

Key features:

Polypropylene Body

The polypropylene body of the HI-1285 houses all three sensors within a sturdy, single body design. This body material is suitable for a wide range of applications and excels in measurements with portable meters due to its durability. The fins around the spherical glass pH bulb minimises breakage due to accidental bumping or dropping of the electrode. The polypropylene plastic is a high-quality plastic that is chemically resistant to many aggressive chemicals.

Built-In Temperature Sensor

pH and EC/TDS readings must be temperature compensated in order to obtain accurate results. The built-in temperature sensor of the HI-1285 provides a speedy temperature reading which is then used to adjust the pH and EC/TDS results accordingly.

Amperometric EC/TDS Sensor

EC/TDS readings are performed by a two-pin amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins determines the amount of dissolved ionic solids present.

Pre-Amplified pH Electrode

The pH electrode circuit has a built-in amplifier that serves to reduce the effects of electrical noise on the high impedance pH measurement. Electrical noise can come from motors and pumps that are common in greenhouses. The single reference junction design of the pH electrode has a cloth junction that allows ion movement between the inner gel electrolyte and the sample being measured. The advantage of the cloth junction is that it can be extracted from the probe, exposing a fresh surface when readings become drifty or erratic. These features make this probe ideal for use in fertiliser solutions.

DIN Connector

The HI-1285 uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI-1285 is designed for use with Hanna’s HI-9813, HI-9812, and HI-9811 portable multiparameter meters.

Läs mer

Reference Single, Ag/AgCl
Junction Cloth
Connector Multi-pin
Electrolyte Gel
Max Pressure 0.1 bar
Range 0 to 13 pH; EC; 0 to 60°C (32 to 140°F)
Tip Shape Spheric (dia: 8 mm)
Temperature Sensor Yes
Amplifier Yes
Body Material Polypropylene
Cable 7-pole; 2 m (6.6')
Recommended Use Greenhouses, hydroponics, environmental monitoring, water treatment, boilers, cooling towers