HI-749 CHROMIUM VI LOW RANGE HANDHELD COLORIMETER, CHECKER HC
HI-749
Ideal for water quality testing, the HI-749 Checker is a simple, accurate, and cost effective way to measure low ranges of Chromium VI in fresh water.
Checker®HC is supplied with reagents for 6 tests. Use code HI-749-25 (25 tests) for future purchases.
Ideal for water quality testing (not suitable for cold water aquarium or salt water marine tanks)
The HI-749 Checker is a simple, accurate, and cost effective way to measure low ranges of chromium VI in fresh water.
Designed as a more accurate alternative to chemical test kits, the HI-749 provides quick, accurate results in four easy steps.
The HI-749 uses an adaptation of the ASTM Manual of Water and Environmental Technology D1687-92, Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.
Features:
- Small palm-sized design
- Accurate from ±2 ppb ±4% of reading
- Dedicated to a single parameter
- Uses a single AAA battery
- Auto Power Off after 10 minutes in inactivity
- Built-in timer for timed reaction readings
Ideal for:
- Water Quality
- Education
- Plating
- Environmental
Order Information:
The HI-749 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of chromium VI LR reagent - re-ordering information HI-749-25 x 25 tests), 1 x 1.5V AAA battery, and an instruction manual.
Also available: Calibration set HI-749-11.
Four steps. One click. Instant Readout.
1. ‘Zero’ the Checker®HC with your vial & water sample inside
2. Take the vial out and add your reagent
3. Place your vial into your Checker®HC
4. Press the button and read the results
Use HI-749-25 Reagents with the Chromium VI LR Handheld Colorimeter - Checker®HC x 25 tests.
Use HI-749-11 Calibration Check Set with the Chromium VI LR Handheld Colorimeter - Checker®HC.
Läs mer
Range | 0 to 300 ppb | |
Resolution | 1 ppb | |
Accuracy (@25°C/77°F) | ±2 ppb ±4% of reading | |
Measurement Method | Colorimetric | |
Light Source | LED @525 nm | |
Light Detector | Silicon photocell | |
Method | Adaptation of ASTM Manual of Water & Environmental Technology, D1687-92, Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample. | |
Power Supply | Battery - 1 x 1.5V AAA | |
Power Auto Off | After 10 min. of inactivity | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.) |