HI-935012

A NEW must have meter for brewers. The HI-935012 thermometer has a 1m long Stainless Steel probe that reaches into beer kettles easily with safety in mind.

Temperatur
Brewing

2 050.39 kr Exl. moms
2 562.98 kr (inkl. moms)
Beskrivning Specifikation Manuals

Hanna Instruments manufactures the HI-935012 Beer Thermometer to meet the tough environment encountered in the brewing industry.

The IP65 compatible casing protects the thermometer from splashes and spills that may occur during brewing. Its durable design ensures its capabilities of overseeing measurements at all stages of the brewing process.

Features:

  • 1m Stainless Steel Thermistor Temperature Probe (FC762N2) – interchangeable with FC762 series thermistor probes
  • Cal Check technology
  • IP67 rated
  • Measures temperature from -200 to 120.0˚C
  • Auto-off capability
  • Probe error messages
  • Carry case
  • Large LCD
  • Stability indicator
  • Long battery life
  • Includes blue shockproof boot (HI-710026)

The meter is specifically designed for measuring the temperature in many chemical processes that take place during the beer production including mashing, wort separation, fermentation and finally packaging, distribution and aging.

Both air temperature and product internal temperature can be measured with this thermometer.

The dedicated probe FC762N2 shaft is designed for continuous contact with foodstuffs in accordance with Regulation (EC) 1935/2004.

Temperature plays a central function in brewing operations. Spot checking temperature throughout the process ensures daily work routines are carried out at the correct temperature, and equipment is operating efficiently. Temperature measurements are made at the hot water tank, the mash tank, the boil kettle, fermenter, bright beer tank and final storage area. Temperature checks provide peace of mind the operation is running smoothly and the batch will be uncompromised.

Läs mer

Range* -20.0 to 120.0˚C
Resolution 0.1˚C
Meter Accuracy @ 23.0˚C ±0.1
Probe Accuracy – FC762N2 ±0.3˚C (-10.0 to 80.0)
Battery type/Life 1.5V AAA x 3, approx. 4500 hours of continuous use
Auto-off user selectable: after 8 minutes, 60 minutes or disabled.
Environment For product internal measurement. Rated operating condition: -20.0 to 50˚C; Limiting condition: -30 to 50˚C; Storage and transportation condition: -40 to 70˚C; Relative humidity 100%
Storage/transport temperature -40 to 70˚C
Dimensions 140 x 57 x 28mm
Weight 175g
Case ingress protection rating IP67

*The measurement range may be limited by probe type and applies to the probe shaft.