+46 300 40 40 18
Beställ innan kl 16.00 för leverans dagen efter. Endast vardagar

Currency: SEK

Menu

In Stock 2 objekt Tillgänglig

HI-97105C

The HI-97105C Hanna Marine Master Photometer provides a multiparameter solution for accurately measuring the water in saltwater aquariums. This fish tank photometer measures vital parameters that provide insight into the quality of water, which is key for maintaining proper aquarium maintenance and care. Marine pH, alkalinity, ammonia, calcium, magnesium, LR and HR nitrate, ULR nitrite and ULR phosphate can all be measured with this multipurpose photometer. 

This Marine Master Multiparameter Photometer is contained in an easy-to-carry hard-wearing case, including several reagent starter kits covering the most vital parameters plus accessories for convenient, reliable measurement.

Alkalinity, Calcium, Nitrate, Nitrite, pH, Phosphate

4 834 kr Exl. moms
6 042 kr (inkl. moms)
Beskrivning Specifikation Manuals

Each HI-97105C is supplied with:

  • Sample cuvette (2 pcs.)
  • Sample cuvette cap (2 pcs.)
  • Marine pH reagent, 30 mL dropper (1 pc.)
  • Marine Alkalinity reagent, 30 mL (1 pc.)
  • Marine Calcium reagent A, 30 mL (1 pc.)
  • Marine Calcium reagent B starter kit (reagent for 25 tests)
  • Marine Nitrate High Range starter kit (reagent for 25 tests)
  • Marine Nitrite Ultra Low Range starter kit (reagent for 25 tests)
  • Marine Phosphate Ultra Low Range starter kit (reagent for 25 tests)
  • 1 mL graduated syringe with tip (2 pcs.)
  • Mini pipette with tip (1 pc.)
  • 3 mL Pasteur pipette (2 pcs.)
  • 1.5V AA Alkaline batteries (3 pcs.)
  • Cloth for wiping cuvettes
  • Scissors
  • Instrument quality certificate
  • Instruction manual

About the photometer

The HI-97105 is designed to accurately determine pH, Alkalinity, Calcium, Nitrate, Nitrite, and Phosphate levels in aquariums and marine biology applications. The HI-97105 Marine Master Photometer combines accuracy and ease of use in a simple, portable design.

The advanced optical system provides lab-quality accuracy, while its user-friendly design is easy for any aquarium user, making it the perfect photometer for your water quality testing needs.

  • No warm up time needed before taking a measurement.
  • Tutorial mode for easy step-by-step instructions
  • CAL CheckTM for performance verification and calibration

Better Features for Better Testing

Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations, so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.

The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.

When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.

Data Logging

Missed a measurement? No need to worry because your photometer will automatically log the last 50 measurements. The results can be viewed instantly using the Log Recall Menu.

CAL CheckTM Validation

Hanna’s exclusive CAL CheckTM feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL CheckTM standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.

Advanced Optical System

A Light Emitting Diode (LED) provides more light while using less power, and a narrow band interference filter results in more accurate and repeatable readings.

Built Better

Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.

Portable Design

Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle - day or night. The supplied AA batteries provide life for more than 800 measurements.

We believe that buying a meter should be simple. Your HI-97105 photometer has many of the necessary accessories needed for successful measurements.

Läs mer

Alkalinity, Marine Range 0.0 to 20.0 dkH 0 to 357 ppm (as CaCo3)
Alkalinity, Marine Resolution 0.1 dkH
Alkalinity, Marine Accuracy ±0.3 dKH ±5 % of reading at 25 °C ±5 ppm ±5 % of reading at 25 °C
Alkalinity, Marine Method Colorimetric Method - The reaction causes a distinctive range of colours from yellow to greenish blue to develop
Ammonia, Marine Range 0.00 to 2.50 ppm (as NH₃)
Ammonia, Marine Resolution 0.01 ppm
Ammonia, Marine Accuracy ±0.05 ppm ±5% of reading at 25°C
Ammonia, Marine Method Adaptation of the Salicylate Method
Ammonia, Marine LED 610 nm
Calcium, Marine Range 200 to 600 ppm
Calcium, Marine Resolution 1 ppm
Calcium, Marine Accuracy ±6 % of reading at 25 °C
Calcium, Marine Method Adaptation of the Zincon Method
Marine Magnesium
Range 1000 to 1800 ppm (as Mg2+)
Resolution 5 ppm
Accuracy ±5% of reading at 25 °C
Method Adaptation of the Colorimetric EDTA Method using calmagite indicator
LED 610 nm
Nitrate Range 0.00 to 5.00 ppm (as No3¯) 0.0 to 75.0 ppm (as No3¯)
Nitrate Resolution 0.01 ppm 0.1 ppm
Nitrate Accuracy 0 to 200 ppb (as No2¯-N)
Nitrate Method Adaptation of the Zincon Method Colorimetric Method The reaction between nitrate and the reagent causes a pink/violet tint in the sample.
Nitrite, Marine ULR Range 0 to 200 ppb (as No2¯-N)
Nitrite, Marine ULR Resolution 1 ppb
Nitrite, Marine ULR Accuracy ±10 ppb ±4 % of reading at 25 °C
Nitrite, Marine ULR Method Adaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample.
pH Range 6.3 to 8.6 pH
pH Resolution 0.1 pH
pH Accuracy ±0.2 pH of reading at 25°C
pH Method Colorimetric Adaptation of the Phenol Red Method
Phosphate, ULR Range 0.00 to 0.90 ppm
Phosphate, ULR Resolution 0.01 ppm
Phosphate, ULR Accuracy ±0.02 ppm ±5 % of reading at 25 °C
Phosphate, ULR Method Adaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample.
Light Source light emitting diode
Light Detector Silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Logging 200 readings
Power Supply 1.5 V AA Alkaline (3 pcs.)
Battery Life > 800 measurements (without backlight)
Auto-off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non serviceable
Dimensions 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0")
Weight 380 g (13.4 oz.); with batteries
Warranty 2 years
Reagents, CAL Check Standards & accessories - buy separately:
Reagent sets
HI-758‑26 Marine Calcium Reagent - 25 tests
HI-764‑25 Marine Nitrite ULR Reagent - 25 tests
HI-772‑26 Marine Alkalinity Reagent - 25 tests
HI-774‑25 Marine Phosphate ULR Reagent - 25 tests
HI-780‑25 Marine pH Reagent - approximately 100 tests
HI-781‑25 Marine Nitrate LR Reagent - 25 tests
HI-782‑25 Marine Nitrate HR Reagent - 25 tests
HI-783-25 Marine Magnesium Reagents - 25 tests
HI-784-25 Marine Ammonia Reagent - 25 tests
HI-97105‑11 CAL Check™ standards for HI-97105 - cuvette kit
Other Accessories
HI-70436M Deionized water (230 mL)
HI-7101418 Blue carrying case for HI-97105C
HI-731318 Cloth for wiping cuvettes (4 pcs.)
HI-731331 Glass cuvette (4 pcs.)
HI-731360 Glass cuvette with cap (2 pcs.)
HI-731336N Cap for glass cuvette (4 pcs.)
HI-731339P 0.1 mL mini pipette
HI-731349P Tip for 0.1 mL mini pipette (10 pcs.)
HI-740142P 1 mL graduated syringe (10 pcs.)
HI-740143 1 mL graduated syringe (6 pcs.)
HI-740144P Plastic tip for 5 mL syringe (10 pcs.)
HI-740157P Plastic refilling pipette (20 pcs.)
HI-740226 5 mL graduated syringe (1 pc.)
HI-740228 Filter disc (25 pcs.)
HI-740270 10 mL syringe with Luer Lock (1 pc.)
HI-740271 Filter holder with Luer Lock (1 pc.)
HI-740272 16 gauge blunt needle (6 pcs.)
HI-740273 Marine Nitrate LR measurement kit (1 pc.)
HI-93703‑50 Cuvette cleaning solution (230 mL)

Liknande produkter